India’s heat-pump specialist · 30 years of engineering
The complete range

Six families. Every hot-water job in India.

From a 200 L All-in-One for a flat to 120 °C process water for industry — all engineered around the same efficiency, and all supported by one team.

6product families
3.5–220 kWcapacity range
−30 → 120 °Coperating envelope
range hero — product line-up
01Domestic

Homes and villas, up to 85% cheaper.

All-in-One units put the tank and heat pump in one footprint. Split units pair a compact outdoor heat pump with your choice of storage tank. Hot & Cold models deliver heating and cooling from one system, 8 °C to 60 °C.

to 75 °C hybrid200–500 L tanks220–240 V / 1-ph
domestic unit — installed on terrace
All-in-One

All-in-One — TT-ALL

Tank and heat pump in one unit. The simplest replacement for an electric geyser.

Tank
200 / 300 / 420 L
Water temp
65 °C eco · 75 °C hybrid
COP
3.85–4.07
Specs & datasheet →
Split

Split, hot only — TT-MNB

Compact outdoor heat pump paired with your choice of storage tank.

Capacity
3.5–9.3 kW
Matched tank
200–500 L
COP
4.0–4.13
Specs & datasheet →
Hot & Cold

Split, hot & cold

Heating and cooling from one system, for homes that want both.

Output
8 °C to 60 °C
Modes
heat / cool
Supply
220–240 V / 1-ph
Specs & datasheet →
hotel plant room — modular bank
02Commercial

Hotels, hospitals, institutions.

Single- and multi-compressor systems from 14 to 180 kW, sized to demand — with capacity and specifications your MEP consultant can design around. Hot & Cold variants deliver 8 °C to 60 °C from one system.

14–180 kWCOP ~4.2tube-in-shell
Commercial DHW

Standard — TT-CM 14–50

Bulk hot water for guest rooms, wards, kitchens and apartments.

Capacity
14–50 kW
Water temp
55 °C rated · 60 °C max
Compressor
Copeland scroll
Specs & datasheet →
Hot & Cold

Large split — TT-CM 70–180

For hotels, resorts, hospitals, hostels and large institutions.

Capacity
70–180 kW
Hot water ΔT40
1,510–3,870 L/h
Compressors
2 or 4 scroll
Specs & datasheet →
Inverter

Hot & Cold option

Heating and cooling from one system where the building needs both.

Output
8 °C to 60 °C
Supply
380–415 V / 3-ph
Refrigerant
R410A / R407C
Specs & datasheet →
03Swimming Pool

Swim season, all year.

Titanium condensers are built specifically for treated pool water. Units are sized by pool volume, from a private home pool to a large commercial or resort pool.

COP up to 6.9titanium condenser11–220 kW
resort pool — heated

TT-SP 11–50

Home pools, jacuzzis, spa and physiotherapy pools.

Capacity
11–50 kW
COP
6.7–6.8
Specs →

TT-SP 65–220

Large commercial and resort pools, two or four compressors.

Capacity
65–220 kW
COP
up to 6.9
Specs →
04High-Temperature

Process water to 120 °C — without a boiler.

Engineered for industry, where hot water is a requirement rather than a comfort. The range reaches 80, 95 or 120 °C at a fraction of the energy of conventional heating — for process, pharma, laundries and commercial kitchens.

80 / 95 / 120 °C14.5–114.4 kWR134a · scroll
industrial install — process water
80 °C

80 °C models

Laundries and commercial kitchens. TT-HT 14.5–114.4 kW, COP 4.0–4.2.

95 °C

95 °C models

Food processing and process hot water where 80 °C is not enough.

120 °C

120 °C models

Pharma, chemicals and textile process heat. Engineered per project.

hill-station install — snow
05Cold-Climate (EVI)

Works where ordinary heat pumps stop.

EVI (Enhanced Vapour Injection) technology keeps output and efficiency up as ambient temperature falls — reliable hot water down to −30 °C for hotels, homes and institutions in Jammu & Kashmir, Himachal Pradesh, Uttarakhand and other cold or high-altitude areas.

−30 °Cminimum ambient
TT-EVImodel series
10.3–69.8 kWcapacity
Specs & datasheet →
06Storage Tanks

Store your hot water. Keep it hot.

A heat pump makes the hot water; a good tank keeps it ready. Glass-enamel lining plus a sacrificial anode resists corrosion, and thick insulation keeps standing losses low.

Glass-enamel + anode

Fused-glass lining with a sacrificial anode for long corrosion protection.

200 / 300 / 500 L

Sized to match domestic and light-commercial systems.

50 mm insulation

Minimises standing heat loss between draw-offs.

Electric backup 3–5 kW

Built-in heater for peak demand, with T&P safety valves.

Side by side

Compare the range at a glance.

FamilyCapacity / modelsWater temperatureAmbientTypical use
DomesticAll-in-One 200–420 L · Split 3.5–9.3 kW65 °C eco · 75 °C hybrid−7 to 45 °CHomes, flats, villas, farmhouses
CommercialTT-CM 14–180 kW55 °C rated · 60 °C max0 to 45 °CHotels, hospitals, hostels, institutions
Swimming PoolTT-SP 11–220 kW45 °C max pool water−7 to 43 °CPools, spa, clubs, physiotherapy
High-TemperatureTT-HT 14.5–114.4 kW80 / 95 / 120 °C0 to 45 °CProcess, pharma, laundries, kitchens
Cold-Climate (EVI)TT-EVI 10.3–69.8 kW60 °Cdown to −30 °CHill stations, high altitude, cold regions
Storage Tanks200 / 300 / 500 LPairs with Split and Commercial systems

Figures transcribed from the Tempratech heat-pump brochure. Certified performance data is issued per model on the datasheet — confirm before tender use.

Not sure which fits?

Three questions and we'll size it.

Send us the building, the demand and the location — you get a model recommendation and a payback estimate, free.

STEP 01

What kind of building?

Home, hotel, hospital, factory or pool — this sets the family.

STEP 02

How much hot water?

Litres per day and peak hours — this sizes the unit and the tank.

STEP 03

Where is the site?

Climate and water quality decide standard, EVI or high-temp.

Get my recommendation
Site survey before every quote
Installation by our own teams
24×7 service support
AMC plans available
Certified toAHRI 210/240ISO 9001CEIntertekKeymarkRoHSWaterMark

Tell us the job. We’ll name the model.

Thirty years of heat-pump engineering, and a specialist on the other end of the call.